# Beam section sizing # Scope: Cantilever section depth from an allowable elastic end deflection. # Status: illustrative worked example; engineering review pending. # Inputs are example values. Checks are editable example requirements, not standards. length = 300 mm width = 25 mm load = 20 N modulus = 69 GPa limit = 2 mm requiredDepth := (4*load*length^3/(modulus*width*limit))^(1/3) [mm] check depth envelope: requiredDepth <= 20 mm scenario alternative: length = 240 mm