# Wind-turbine power screening # Scope: Rotor swept-area power with supplied power coefficient; no wind distribution. # Status: illustrative worked example; engineering review pending. # Inputs are example values. Checks are editable example requirements, not standards. density = 1.225 kg/m^3 diameter = 2 m speed = 8 m/s coefficient = 0.35 area := pi*diameter^2/4 [m^2] power := density*area*speed^3*coefficient/2 [W] check coefficient below ideal limit: coefficient <= 0.5926 scenario alternative: density = 0.98 kg/m^3