# Micro-hydro power # Scope: Net-head hydro power at supplied total efficiency. # Status: illustrative worked example; engineering review pending. # Inputs are example values. Checks are editable example requirements, not standards. flow = 10 L/s head = 5 m density = 1000 kg/m^3 gravity = 9.81 m/s^2 efficiency = 0.6 power := density*gravity*flow*head*efficiency [W] check power target: power >= 250 W scenario alternative: flow = 8 L/s