# Fan and duct operating point # Scope: Quadratic fan/system pressure intersection; supplied curve coefficients. # Status: illustrative worked example; engineering review pending. # Inputs are example values. Checks are editable example requirements, not standards. shutoff = 300 Pa fanCoefficient = 10000 Pa*s^2/m^6 systemCoefficient = 20000 Pa*s^2/m^6 flow := sqrt(shutoff/(fanCoefficient+systemCoefficient)) [m^3/s] pressure := systemCoefficient*flow^2 [Pa] check airflow target: flow >= 0.08 m^3/s scenario alternative: shutoff = 240 Pa