# Magnetic-circuit reluctance # Scope: Uniform linear core reluctance; supplied relative permeability, no saturation/fringing. # Status: illustrative worked example; engineering review pending. # Inputs are example values. Checks are editable example requirements, not standards. length = 100 mm area = 100 mm^2 relativePermeability = 1000 turns = 100 current = 0.1 A muZero = 0.0000012566370614 H/m reluctance := length/(muZero*relativePermeability*area) [A/Wb] flux := turns*current/reluctance [Wb] density := flux/area [T] check flux density screen: density <= 0.3 T scenario alternative: length = 80 mm