# Water-hammer screening # Scope: Joukowsky instantaneous velocity-change pressure; wave speed supplied. # Status: illustrative worked example; engineering review pending. # Inputs are example values. Checks are editable example requirements, not standards. density = 1000 kg/m^3 waveSpeed = 1000 m/s velocityChange = 1 m/s surge := density*waveSpeed*velocityChange [MPa] check surge budget: surge <= 1.5 MPa scenario alternative: density = 800 kg/m^3