# Orifice flow estimate # Scope: Incompressible sharp-orifice estimate; discharge coefficient supplied. # Status: illustrative worked example; engineering review pending. # Inputs are example values. Checks are editable example requirements, not standards. diameter = 5 mm pressureDrop = 10000 Pa density = 1000 kg/m^3 coefficient = 0.62 flow := coefficient*pi*diameter^2/4*sqrt(2*pressureDrop/density) [L/min] check flow target: flow >= 2 L/min scenario alternative: diameter = 4 mm